CSTV – Coil steam generator vertical

CSTV once trough controlled circulation steam generators fall into the limited capacity category. In addition to the classic benefits of controlled circulation generators, including fast pressurization, total safety against the risk of rupture/boiler explosion, etc., our CSTV generators are characterised by:

Vertical layout, both with three smoke passes. Steam generator can be manufactured too in horizontal  execution without any problematics.

  • High efficiency (90,5%) thanks to the high exchange surface area.
  • High steam quality ,high steam title  (dry steam) thanks to the execution with variable cross section coil, to our special steam/water separator, and to the facility for fine regulation of the water pump flow rate.
  • Easy maintenance For vertical execution bolted upper door fully operable for cleaning purposes or removal of the coil thanks to the bolted upper door, which are fully operable for cleaning purposes or removal of the coil. 
  • Immediate assistance service, thanks to the use of primary brand commercial burners. On-the-spot after-sales service.

Steam capacity: from 200 to 5000 kg/h. bigger capacity o demand
Standard pressure: 12 bar. On request till 140 bar

BBS DIVISION reserves the right to make the changes it deems necessary to improve production.