{"id":1710,"date":"2019-06-27T16:32:40","date_gmt":"2019-06-27T16:32:40","guid":{"rendered":"https:\/\/bbs.mediademo.it\/mixeg-recuperatore-fumi-per-sistema-lamont-navale\/"},"modified":"2019-09-11T13:04:54","modified_gmt":"2019-09-11T13:04:54","slug":"mixeg","status":"publish","type":"page","link":"https:\/\/www.bbsdivision.com\/en\/mixeg\/","title":{"rendered":"MIXEG &#8211; Economizer for mixture (steam and super heated water) production"},"content":{"rendered":"<p>[vc_row type=&#8221;full_width_section&#8221;][vc_column width=&#8221;1\/1&#8243;]<div class=\"templatera_shortcode\"><div  class=\"wpb_row vc_row-fluid full-width-section section  section-no-parallax  stretch   \" data-speed=\"1\" style=\"\"><div class=\"col span_12 color-dark text-align-center\">\n\t<div class=\"vc_col-sm-12 wpb_column column_container col no-padding color-dark\" style=\"\" data-animation=\"\" data-delay=\"\">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h2>BOILERS AND STEAM GENERATORS | MARINE<\/h2>\n\n\t\t<\/div>\n\t<\/div>\n\n\t\t<\/div> \n\t<\/div> \n<\/div><\/div><div  class=\"wpb_row vc_row-fluid standard-section section  section-no-parallax  stretch   \" data-speed=\"1\" style=\"\"><div class=\"col span_12 color-dark left\">\n\t<div class=\"vc_col-sm-12 wpb_column column_container col no-padding color-dark\" style=\"\" data-animation=\"\" data-delay=\"\">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<div class=\"ult-spacer spacer-6b00b7dac59af\" data-id=\"6b00b7dac59af\" data-height=\"40\" data-height-mobile=\"20\" data-height-tab=\"20\" data-height-tab-portrait=\"20\" data-height-mobile-landscape=\"20\" style=\"clear:both;display:block;\"><\/div>\n\t\t<\/div> \n\t<\/div> \n<\/div><\/div><\/div>[\/vc_column][\/vc_row][vc_row text_align=&#8221;center&#8221; row_id=&#8221;prodotto-titolo&#8221;][vc_column width=&#8221;1\/1&#8243;][vc_column_text]<\/p>\n<h1>MIXEG &#8211; Economizer for mixture (steam and super heated water) production<\/h1>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/1&#8243;]<div class=\"divider divider1\" style='margin:30px 0 30px 0 !important;'><\/div>[\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/2&#8243;][vc_column_text]MIXEG is a controlled circulation exhaust gas mixture generator with vertical lay-out. Internal coils are fed by the water pump parallel to gases circulation. Mixture (superheated water\/steam) is produced at saturation water temperature.<\/p>\n<p>Economizer is usually designed at 85% MCR in order to have the possibility to regulate the steam pressure when the ME is running in the range 85-100%. Case by case it is possible to consider larger ranges and design at different % MCR (75-100% or bigger) in accordance with ME characteristics.<\/p>\n<p><b>In standard configuration the economizer<span class=\"Apple-converted-space\">\u00a0 <\/span>is equipped with &#8220;one flap&#8221; internal (or external) damper,<\/b> opened at the steam working pressure. In this situation, smokes flow is through the major transit area to the chimney, avoiding overheating of coil pipes and steam. The movement is progressive, motor controlled, with handle for safety manual operation.<\/p>\n<p>MIXEG steam generators are controlled by centrifugal pumps always running during operation.<\/p>\n<p>The working pressure is maintained with an electronic steam pressure controller that operates the exhaust smokes damper. When the working pressure is reached the damper opens flow the exhaust smokes directly to the chimney. When the steam pressure decreases the damper closes in order to increase exhaust smokes pass through generator coils.<span class=\"Apple-converted-space\">\u00a0<\/span>[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_column_text]The movement is progressive, motor controlled, with handle for safety manual operation.<span class=\"Apple-converted-space\">\u00a0<\/span><\/p>\n<p><b>Option 1.<\/b> The economizer is equipped with an internal double flap damper, operated on the basis of the fluid pressure. The movement is progressive, motor controlled, with handle for safety manual operation. With this configuration, smokes flow can be divided either through central by-pass or through coil pipes. Coil pipe passage area can be completely closed and therefore minimum steam production is close to zero.<\/p>\n<p><b>Option 2<\/b>. The economizer can be designed for the use with external dumping cooler that cools down overproduction of steam.<\/p>\n<p>The fluid temperature is controlled with temperature sensor connected to an electronic temperature controller; in case of high temperature the by-pass valve opens.<\/p>\n<p><b>Standard design pressure: 12 bar<br \/>\n<\/b><b>Capacity till 2.000 kg\/h<br \/>\n<\/b><b>Bigger capacity and design pressure on demand<\/b>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/1&#8243;]<div class=\"ult-spacer spacer-6b00b7dac5ade\" data-id=\"6b00b7dac5ade\" data-height=\"40\" data-height-mobile=\"20\" data-height-tab=\"20\" data-height-tab-portrait=\"20\" data-height-mobile-landscape=\"20\" style=\"clear:both;display:block;\"><\/div>[\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/1&#8243;][vc_single_image image=&#8221;1826&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221;][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/1&#8243;]<div class=\"ult-spacer spacer-6b00b7dac5b19\" data-id=\"6b00b7dac5b19\" data-height=\"40\" data-height-mobile=\"20\" data-height-tab=\"20\" data-height-tab-portrait=\"20\" data-height-mobile-landscape=\"20\" style=\"clear:both;display:block;\"><\/div>[\/vc_column][\/vc_row][vc_row type=&#8221;full_width_section&#8221;][vc_column width=&#8221;1\/1&#8243;]<div class=\"templatera_shortcode\"><div  class=\"wpb_row vc_row-fluid standard-section section  section-no-parallax  stretch   \" data-speed=\"1\" style=\"\"><div class=\"col span_12 color-dark left\">\n\t<div class=\"vc_col-sm-12 wpb_column column_container col no-padding color-dark\" style=\"\" data-animation=\"\" data-delay=\"\">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<div class=\"divider divider1\" style='margin:30px 0 30px 0 !important;'><\/div>\n\t\t<\/div> \n\t<\/div> \n<\/div><\/div><div id=\"nota-prodotti\" class=\"wpb_row vc_row-fluid standard-section section  section-no-parallax  stretch   \" data-speed=\"1\" style=\"\"><div class=\"col span_12 color-dark text-align-center\">\n\t<div class=\"vc_col-sm-12 wpb_column column_container col no-padding color-dark\" style=\"\" data-animation=\"\" data-delay=\"\">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>BBS DIVISION reserves the right to make the changes it deems necessary to improve production.<\/p>\n\n\t\t<\/div>\n\t<\/div>\n\n\t\t<\/div> \n\t<\/div> \n<\/div><\/div><div  class=\"wpb_row vc_row-fluid standard-section section  section-no-parallax  stretch   \" data-speed=\"1\" style=\"\"><div class=\"col span_12 color-dark left\">\n\t<div class=\"vc_col-sm-12 wpb_column column_container col no-padding color-dark\" style=\"\" data-animation=\"\" data-delay=\"\">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<div class=\"ult-spacer spacer-6b00b7dac7a2c\" data-id=\"6b00b7dac7a2c\" data-height=\"40\" data-height-mobile=\"20\" data-height-tab=\"20\" data-height-tab-portrait=\"20\" data-height-mobile-landscape=\"20\" style=\"clear:both;display:block;\"><\/div>\n\t\t<\/div> \n\t<\/div> \n<\/div><\/div><\/div>[\/vc_column][\/vc_row][vc_row type=&#8221;full_width_section&#8221;][vc_column width=&#8221;1\/1&#8243;]<div class=\"templatera_shortcode\"><div  class=\"wpb_row vc_row-fluid full-width-section section  section-no-parallax  stretch bg-stretch  \" data-speed=\"1\" style=\"background-image: url(https:\/\/www.bbsdivision.com\/wp-content\/uploads\/caldaie-bruciatori-boilers-naval-marine-navali.jpg); \"><div class=\"col span_12 color-dark left\">\n\t<div class=\"vc_col-sm-12 wpb_column column_container col no-padding color-dark\" style=\"\" data-animation=\"\" data-delay=\"\">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<div class=\"ult-spacer spacer-6b00b7dac8931\" data-id=\"6b00b7dac8931\" data-height=\"500\" data-height-mobile=\"250\" data-height-tab=\"250\" data-height-tab-portrait=\"250\" data-height-mobile-landscape=\"250\" style=\"clear:both;display:block;\"><\/div>\n\t\t<\/div> \n\t<\/div> \n<\/div><\/div><\/div>[\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"BOILERS AND STEAM GENERATORS | MARINE MIXEG - Economizer for mixture (steam and super heated water) production MIXEG is a controlled circulation exhaust gas mixture generator with vertical lay-out. Internal coils are fed by the water pump parallel to gases circulation. Mixture (superheated water\/steam) is produced at saturation water temperature. Economizer is usually designed at 85% MCR in order to have the possibility to regulate the steam pressure when the ME is running in the range 85-100%. Case by case it is possible to consider larger ranges and design at different % MCR (75-100% or bigger) in accordance with ME characteristics. In standard configuration the economizer\u00a0 is equipped with \"one flap\" internal (or external) damper, opened at the steam working pressure. In this situation, smokes flow is through the major transit area to the chimney, avoiding overheating of coil pipes and steam. The movement is progressive, motor controlled, with handle for safety manual operation. MIXEG steam generators are controlled by centrifugal pumps always running during operation. The working pressure is maintained with an electronic steam pressure controller that operates the exhaust smokes damper. When the working pressure is reached the damper opens flow the exhaust smokes directly to the chimney. [...]","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1710","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.bbsdivision.com\/en\/wp-json\/wp\/v2\/pages\/1710\/"}],"collection":[{"href":"https:\/\/www.bbsdivision.com\/en\/wp-json\/wp\/v2\/pages\/"}],"about":[{"href":"https:\/\/www.bbsdivision.com\/en\/wp-json\/wp\/v2\/types\/page\/"}],"author":[{"embeddable":true,"href":"https:\/\/www.bbsdivision.com\/en\/wp-json\/wp\/v2\/users\/1\/"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bbsdivision.com\/en\/wp-json\/wp\/v2\/comments\/?post=1710"}],"version-history":[{"count":4,"href":"https:\/\/www.bbsdivision.com\/en\/wp-json\/wp\/v2\/pages\/1710\/revisions\/"}],"predecessor-version":[{"id":1829,"href":"https:\/\/www.bbsdivision.com\/en\/wp-json\/wp\/v2\/pages\/1710\/revisions\/1829\/"}],"wp:attachment":[{"href":"https:\/\/www.bbsdivision.com\/en\/wp-json\/wp\/v2\/media\/?parent=1710"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}