{"id":1681,"date":"2019-08-06T09:39:16","date_gmt":"2019-08-06T09:39:16","guid":{"rendered":"https:\/\/bbs.mediademo.it\/2pvmc-generatore-di-vapore-verticale-a-due-giri-di-fumo-combinato-marino\/"},"modified":"2019-09-09T10:14:36","modified_gmt":"2019-09-09T10:14:36","slug":"2pvmc","status":"publish","type":"page","link":"https:\/\/www.bbsdivision.com\/en\/2pvmc\/","title":{"rendered":"2PVMC &#8211; Two passes of smoke steam boiler vertical execution marine with exhaust gas recovery unit"},"content":{"rendered":"<p>[vc_row type=&#8221;full_width_section&#8221;][vc_column width=&#8221;1\/1&#8243;]<div class=\"templatera_shortcode\"><div  class=\"wpb_row vc_row-fluid full-width-section section  section-no-parallax  stretch   \" data-speed=\"1\" style=\"\"><div class=\"col span_12 color-dark text-align-center\">\n\t<div class=\"vc_col-sm-12 wpb_column column_container col no-padding color-dark\" style=\"\" data-animation=\"\" data-delay=\"\">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h2>BOILERS AND STEAM GENERATORS | MARINE<\/h2>\n\n\t\t<\/div>\n\t<\/div>\n\n\t\t<\/div> \n\t<\/div> \n<\/div><\/div><div  class=\"wpb_row vc_row-fluid standard-section section  section-no-parallax  stretch   \" data-speed=\"1\" style=\"\"><div class=\"col span_12 color-dark left\">\n\t<div class=\"vc_col-sm-12 wpb_column column_container col no-padding color-dark\" style=\"\" data-animation=\"\" data-delay=\"\">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<div class=\"ult-spacer spacer-6b00b808c118a\" data-id=\"6b00b808c118a\" data-height=\"40\" data-height-mobile=\"20\" data-height-tab=\"20\" data-height-tab-portrait=\"20\" data-height-mobile-landscape=\"20\" style=\"clear:both;display:block;\"><\/div>\n\t\t<\/div> \n\t<\/div> \n<\/div><\/div><\/div>[\/vc_column][\/vc_row][vc_row text_align=&#8221;center&#8221; row_id=&#8221;prodotto-titolo&#8221;][vc_column width=&#8221;1\/1&#8243;][vc_column_text]<\/p>\n<h1>2PVMC &#8211; Two passes of smoke steam boiler vertical execution marine with exhaust gas recovery unit<\/h1>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/1&#8243;]<div class=\"divider divider1\" style='margin:30px 0 30px 0 !important;'><\/div>[\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/2&#8243;][vc_column_text]The steam generator mod. <b>2PVMC<span class=\"Apple-converted-space\">\u00a0 <\/span><\/b>is a single block generator with two smoke circuits, vertical execution.<\/p>\n<p>It is provided with pressurized combustion and works fully automatically. It is supplied \u201cpackaged\u201d: it is complete with all accessories. The supply includes the generator itself and the following auxiliary components:<span class=\"Apple-converted-space\">\u00a0 \u00a0<\/span><\/p>\n<ul>\n<li>1 primary feed pump<\/li>\n<li>1 electrical control panel<\/li>\n<li>2 level indicators<\/li>\n<li>regulation and safety devices<\/li>\n<li>valves and accessories<\/li>\n<\/ul>\n<p>All these components are pre-mounted on the generator or on its base.<\/p>\n<p>The generator basically consists of a boiler including the shell, pipe plates, the combustion chamber and the smoke pipes. <span class=\"Apple-converted-space\"><br \/>\n<\/span>The shell is equipped with small blocks for steam intake, safety valves, the manometer, pressure gauges and a conductivity control probe, if necessary. There is also a maintenance hole, a handrail and lifting eyebolts. <span class=\"Apple-converted-space\">\u00a0<\/span>The pipe plates (front and rear) are flat, welded on the plating and are provided with holes for inserting the smoke pipes. <span class=\"Apple-converted-space\"><br \/>\n<\/span>The combustion chamber is cylindrical, open at the rear.<br \/>\nThe smoke pipes, which are welded on the pipe plates, are located around the combustion chamber.<span class=\"Apple-converted-space\">\u00a0<\/span>[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_column_text]The inside of the boiler and all accessories are accessible for cleaning and maintenance. They can be inspected both by users and the body responsible for controlling the generator.<span class=\"Apple-converted-space\">\u00a0<\/span><\/p>\n<p>The unit is provided with all safety accessories, as established by the regulations in force. <span class=\"Apple-converted-space\">\u00a0<\/span><\/p>\n<p>The pressure and the water level can be adjusted from the electrical panel which enables automatic operation. Three electrically and mechanically independent devices are used for controlling the make-up pump and signaling the lack of water. <span class=\"Apple-converted-space\">\u00a0<\/span><\/p>\n<p>All devices are already connected with the hydraulic and electrical network.<span class=\"Apple-converted-space\">\u00a0<\/span><\/p>\n<p><b>The exhaust gas recovery unit <\/b>is designed for steam generation capacity based on available exhaust smokes flow and temperature.<\/p>\n<p>Steam generation is usually designed at 85% MCR, in case of steam excess production a dumpin cooler is requested.<\/p>\n<p><b>Standard design pressure: 12 bar<br \/>\n<\/b><b>Boiler capacity from 1.000 kg\/h to 5.000 kg\/h<br \/>\n<\/b><b>Bigger capacity and design pressure on demand<\/b>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/1&#8243;]<div class=\"ult-spacer spacer-6b00b808c1284\" data-id=\"6b00b808c1284\" data-height=\"40\" data-height-mobile=\"20\" data-height-tab=\"20\" data-height-tab-portrait=\"20\" data-height-mobile-landscape=\"20\" style=\"clear:both;display:block;\"><\/div>[\/vc_column][\/vc_row][vc_row text_align=&#8221;center&#8221;][vc_column width=&#8221;1\/1&#8243;][vc_single_image image=&#8221;881&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221;]<a href=\"\/wp-content\/uploads\/6.3.2-105EXD-2PVMC-40001300-8-BAR-EXTERNAL-DIMENSION.pdf\" target=\"_blank\" class=\"button red medium \" style=\"border-radius: 6px;\">Download PDF<\/a>[\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/1&#8243;]<div class=\"ult-spacer spacer-6b00b808c12e3\" data-id=\"6b00b808c12e3\" data-height=\"40\" data-height-mobile=\"20\" data-height-tab=\"20\" data-height-tab-portrait=\"20\" data-height-mobile-landscape=\"20\" style=\"clear:both;display:block;\"><\/div>[\/vc_column][\/vc_row][vc_row type=&#8221;full_width_section&#8221;][vc_column width=&#8221;1\/1&#8243;]<div class=\"templatera_shortcode\"><div  class=\"wpb_row vc_row-fluid standard-section section  section-no-parallax  stretch   \" data-speed=\"1\" style=\"\"><div class=\"col span_12 color-dark left\">\n\t<div class=\"vc_col-sm-12 wpb_column column_container col no-padding color-dark\" style=\"\" data-animation=\"\" data-delay=\"\">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<div class=\"divider divider1\" style='margin:30px 0 30px 0 !important;'><\/div>\n\t\t<\/div> \n\t<\/div> \n<\/div><\/div><div id=\"nota-prodotti\" class=\"wpb_row vc_row-fluid standard-section section  section-no-parallax  stretch   \" data-speed=\"1\" style=\"\"><div class=\"col span_12 color-dark text-align-center\">\n\t<div class=\"vc_col-sm-12 wpb_column column_container col no-padding color-dark\" style=\"\" data-animation=\"\" data-delay=\"\">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>BBS DIVISION reserves the right to make the changes it deems necessary to improve production.<\/p>\n\n\t\t<\/div>\n\t<\/div>\n\n\t\t<\/div> \n\t<\/div> \n<\/div><\/div><div  class=\"wpb_row vc_row-fluid standard-section section  section-no-parallax  stretch   \" data-speed=\"1\" style=\"\"><div class=\"col span_12 color-dark left\">\n\t<div class=\"vc_col-sm-12 wpb_column column_container col no-padding color-dark\" style=\"\" data-animation=\"\" data-delay=\"\">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<div class=\"ult-spacer spacer-6b00b808c2dc4\" data-id=\"6b00b808c2dc4\" data-height=\"40\" data-height-mobile=\"20\" data-height-tab=\"20\" data-height-tab-portrait=\"20\" data-height-mobile-landscape=\"20\" style=\"clear:both;display:block;\"><\/div>\n\t\t<\/div> \n\t<\/div> \n<\/div><\/div><\/div>[\/vc_column][\/vc_row][vc_row type=&#8221;full_width_section&#8221;][vc_column width=&#8221;1\/1&#8243;]<div class=\"templatera_shortcode\"><div  class=\"wpb_row vc_row-fluid full-width-section section  section-no-parallax  stretch bg-stretch  \" data-speed=\"1\" style=\"background-image: url(https:\/\/www.bbsdivision.com\/wp-content\/uploads\/caldaie-bruciatori-boilers-naval-marine-navali.jpg); \"><div class=\"col span_12 color-dark left\">\n\t<div class=\"vc_col-sm-12 wpb_column column_container col no-padding color-dark\" style=\"\" data-animation=\"\" data-delay=\"\">\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<div class=\"ult-spacer spacer-6b00b808c3c7b\" data-id=\"6b00b808c3c7b\" data-height=\"500\" data-height-mobile=\"250\" data-height-tab=\"250\" data-height-tab-portrait=\"250\" data-height-mobile-landscape=\"250\" style=\"clear:both;display:block;\"><\/div>\n\t\t<\/div> \n\t<\/div> \n<\/div><\/div><\/div>[\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"BOILERS AND STEAM GENERATORS | MARINE 2PVMC - Two passes of smoke steam boiler vertical execution marine with exhaust gas recovery unit The steam generator mod. 2PVMC\u00a0 is a single block generator with two smoke circuits, vertical execution. It is provided with pressurized combustion and works fully automatically. It is supplied \u201cpackaged\u201d: it is complete with all accessories. The supply includes the generator itself and the following auxiliary components:\u00a0 \u00a0 1 primary feed pump 1 electrical control panel 2 level indicators regulation and safety devices valves and accessories All these components are pre-mounted on the generator or on its base. The generator basically consists of a boiler including the shell, pipe plates, the combustion chamber and the smoke pipes. The shell is equipped with small blocks for steam intake, safety valves, the manometer, pressure gauges and a conductivity control probe, if necessary. There is also a maintenance hole, a handrail and lifting eyebolts. \u00a0The pipe plates (front and rear) are flat, welded on the plating and are provided with holes for inserting the smoke pipes. The combustion chamber is cylindrical, open at the rear. The smoke pipes, which are welded on the pipe plates, are located around the combustion chamber.\u00a0 [...]","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1681","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.bbsdivision.com\/en\/wp-json\/wp\/v2\/pages\/1681\/"}],"collection":[{"href":"https:\/\/www.bbsdivision.com\/en\/wp-json\/wp\/v2\/pages\/"}],"about":[{"href":"https:\/\/www.bbsdivision.com\/en\/wp-json\/wp\/v2\/types\/page\/"}],"author":[{"embeddable":true,"href":"https:\/\/www.bbsdivision.com\/en\/wp-json\/wp\/v2\/users\/1\/"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bbsdivision.com\/en\/wp-json\/wp\/v2\/comments\/?post=1681"}],"version-history":[{"count":2,"href":"https:\/\/www.bbsdivision.com\/en\/wp-json\/wp\/v2\/pages\/1681\/revisions\/"}],"predecessor-version":[{"id":1683,"href":"https:\/\/www.bbsdivision.com\/en\/wp-json\/wp\/v2\/pages\/1681\/revisions\/1683\/"}],"wp:attachment":[{"href":"https:\/\/www.bbsdivision.com\/en\/wp-json\/wp\/v2\/media\/?parent=1681"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}